Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 280 mm

d

N/A 11.024 in

D

N/A 13.976 in

L

N/A 2.362 in

L1

N/A 2.598 in

L2

N/A 3.307 in

Mt

N/A 129,009 ft-lbs

Fax

N/A 280,870 lbs.F

Ps

N/A 28611 psi

Ph

N/A 22566 psi
DN1 N/A 24.256 in

Locking Screws Quantity

N/A 32

Locking Screws Size

N/A M18 x 60

Ma-Locking Screws

N/A 299 ft-lbs

dB-Locking Screws

N/A M22

Hub Machining Tolerance

N/A 0.005 in

Shaft Machining Tolerance

N/A -0.005 in

Weight

N/A 43.00 lb

UPC Code

N/A 044861087626

Competitor Part Number

Alternate Part Number

N/A 103214855 2748086 PL280X355 AS RfN 7012 280 x 355 SLD 1500 MM 280X355 T401280 TLK 200 280X355
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform