Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 260 mm

d

N/A 10.236 in

D

N/A 12.795 in

L

N/A 1.969 in

L1

N/A 2.205 in

L2

N/A 2.835 in

Mt

N/A 104,699 ft-lbs

Fax

N/A 245,478 lbs.F

Ps

N/A 32315 psi

Ph

N/A 25852 psi
DN1 N/A 24.613 in

Locking Screws Quantity

N/A 34

Locking Screws Size

N/A M16 x 50

Ma-Locking Screws

N/A 218 ft-lbs

dB-Locking Screws

N/A M20

Hub Machining Tolerance

N/A 0.005 in

Shaft Machining Tolerance

N/A -0.005 in

Weight

N/A 28.00 lb

UPC Code

N/A 044861087602

Competitor Part Number

Alternate Part Number

N/A 103219557 1748084 B401260 PL260X325 AS RfN 7012 260 x 325 SLD 1500 MM 260X325 TLK 200 260X325
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform