Print Back
Single-taper, self-centering design with mounting flange for use in through-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Locking Assembly

Specifications

Shaft Size

N/A 7/8 in

d

N/A 0.875 in

D

N/A 1.563 in

D1

N/A 1.750 in

L

N/A 0.591 in

L1

N/A 0.754 in

L2

N/A 0.984 in

L3

N/A 1.181 in

Mt

N/A 2,309 in-lbs

Fax

N/A 5,277 lbs.F

Ps

N/A 27,070 psi

Ph

N/A 15,159 psi
DN1 N/A 2.219 in

Locking Screws Quantity

N/A 6

Locking Screws Size

N/A M5 x 18

Ma-Locking Screws

N/A 89 in-lbs

Hub Machining Tolerance

N/A 0.001 in

Shaft Machining Tolerance

N/A -0.001 in

Weight

N/A 0.40 lb

UPC Code

N/A 044861046609
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.