CAD (0)
  • Cart is empty
Single-taper, self-centering design with mounting flange for use in through-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Locking Assembly

Specifications

Shaft Size

N/A 1 1/8 in

d

N/A 1.125 in

D

N/A 1.875 in

D1

N/A 2.000 in

L

N/A 0.669 in

L1

N/A 0.829 in

L2

N/A 1.102 in

L3

N/A 1.299 in

Mt

N/A 4,453 in-lbs

Fax

N/A 7,916 lbs.F

Ps

N/A 27,900 psi

Ph

N/A 16,740 psi
DN1 N/A 2.771 in

Locking Screws Quantity

N/A 9

Locking Screws Size

N/A M5 x 18

Ma-Locking Screws

N/A 89 in-lbs

Hub Machining Tolerance

N/A 0.001 in

Shaft Machining Tolerance

N/A -0.001 in

Weight

N/A 0.60 lb

UPC Code

N/A 044861046623
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.