Print Back
Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 14 mm

d

N/A 0.551 in

D

N/A 1.260 in

L

N/A 0.551 in

L1

N/A 0.709 in

L2

N/A 0.846 in

L3

N/A 1.004 in

Mt

N/A 26 ft-lbs

Fax

N/A 1146 lbs.F

Ps

N/A 6,382 psi

Ph

N/A 2756 psi
DN1 N/A 1.382 in

Locking Screws Quantity

N/A 4

Locking Screws Size

N/A M4 x 12

Ma-Locking Screws

N/A 2 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 0.20 lb
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform