Print Back
Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Locking Assembly

Specifications

Shaft Size

N/A 3 1/4 in

d

N/A 3.250 in

D

N/A 4.921 in

L

N/A 0.945 in

L1

N/A 1.102 in

L2

N/A 1.496 in

Mt

N/A 5,660 ft-lbs

Fax

N/A 41,793 lbs.F

Ps

N/A 36101 psi

Ph

N/A 23841 psi
DN1 N/A 8.877 in

Locking Screws Quantity

N/A 16

Locking Screws Size

N/A M10 x 25

Ma-Locking Screws

N/A 51 ft-lbs

dB-Locking Screws

N/A M12

Hub Machining Tolerance

N/A 0.004 in

Shaft Machining Tolerance

N/A -0.003 in

Weight

N/A 3.30 lb

UPC Code

N/A 044861075784

Competitor Part Number

Alternate Part Number

N/A 103235286 2735292 87793253 RfN 7012 3.25 x 4.921 SLD 1500 IN 3-1/4 T402304 TLK 200 3 1/4
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform