Print Back
Double-taper, non-self-centering design for use in counter-bored components. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Locking Assembly

Specifications

Shaft Size

N/A 2 in

d

N/A 2.000 in

D

N/A 3.346 in

L

N/A 0.787 in

L1

N/A 0.945 in

L2

N/A 1.260 in

Mt

N/A 953 ft-lbs

Fax

N/A 11,436 lbs.F

Ps

N/A 11,621 psi

Ph

N/A 6962 psi
DN1 N/A 4.239 in

Locking Screws Quantity

N/A 14

Locking Screws Size

N/A M8 x 22

Ma-Locking Screws

N/A 16 ft-lbs

dB-Locking Screws

N/A M10

Hub Machining Tolerance

N/A 0.003 in

Shaft Machining Tolerance

N/A -0.003 in

Weight

N/A 1.50 lb
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform