CAD (0)
  • Cart is empty
Wide, shallow taper, self-centering design for use in through-bored components with extremely high torque and/or bending requirements. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 120 mm

d

N/A 4.724 in

D

N/A 6.496 in

L

N/A 3.543 in

L1

N/A 4.016 in

L2

N/A 4.488 in

Mt

N/A 31,283 ft-lbs

Fax

N/A 158,920 lbs.F

Ps

N/A 32377 psi

Ph

N/A 23547 psi
DN1 N/A 11.612 in

Locking Screws Quantity

N/A 14

Locking Screws Size

N/A M12 x 80

Ma-Locking Screws

N/A 107 ft-lbs

Hub Machining Tolerance

N/A 0.003 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 14.00 lb

UPC Code

N/A 044861087589

Competitor Part Number

Alternate Part Number

N/A 103217295 2748100 7005 ECOLOC 120 x 165 B121120 PL120X165 AD SLD 2600 MM 120X165 TLK 452 120X165
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform