CAD (0)
  • Cart is empty
Single-taper, self-centering design with mounting flange for use in through-bored components with smaller pitch/outside diameters. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 42 mm

d

N/A 1.654 in

D

N/A 2.165 in

D1

N/A 2.795 in

D2

N/A 3.071 in

L

N/A 1.260 in

L1

N/A 1.850 in

L2

N/A 2.126 in

L3

N/A 2.362 in

Mt

N/A 691 ft-lbs

Fax

N/A 10,024 lbs.F

Ps

N/A 12,763 psi

Ph

N/A 9747 psi
DN1 N/A 2.698 in

Locking Screws Quantity

N/A 8

Locking Screws Size

N/A M6 x 18

Ma-Locking Screws

N/A 13 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 1.70 lb

UPC Code

N/A 044861077061

Competitor Part Number

Alternate Part Number

N/A 103215424 2735372 PL042X055 TF SLD 1900 MM 42X45 T8042 TLK 110 42X55
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.