Single-taper, self-centering design with mounting flange for use in through-bored components with smaller pitch/outside diameters. Mounted component remains fixed axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 16 mm

d

N/A 0.630 in

D

N/A 0.945 in

D1

N/A 1.575 in

D2

N/A 1.732 in

L

N/A 0.630 in

L1

N/A 1.161 in

L2

N/A 1.437 in

L3

N/A 1.673 in

Mt

N/A 99 ft-lbs

Fax

N/A 3,759 lbs.F

Ps

N/A 25128 psi

Ph

N/A 16752 psi
DN1 N/A 1.397 in

Locking Screws Quantity

N/A 3

Locking Screws Size

N/A M6 x 16

Ma-Locking Screws

N/A 13 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 0.60 lb

UPC Code

N/A 044861077047

Competitor Part Number

Alternate Part Number

N/A 101936576 2735351 7110 ECOLOC 16 x 24 B801016 PL016X024 TF SLD 1900 MM 16X24 TLK 110 16X24
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi. For details see Hub Strength in Technical Information.