CAD (0)
  • Cart is empty
Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 80 mm

d

N/A 3.150 in

D

N/A 4.724 in

L

N/A 0.945 in

L1

N/A 1.201 in

L2

N/A 1.594 in

L3

N/A 1.988 in

Mt

N/A 3,990 ft-lbs

Fax

N/A 30,403 lbs.F

Ps

N/A 27,099 psi

Ph

N/A 18066 psi
DN1 N/A 7.229 in

Locking Screws Quantity

N/A 8

Locking Screws Size

N/A M10 x 30

Ma-Locking Screws

N/A 51 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 4.10 lb

UPC Code

N/A 044861074770

Competitor Part Number

Alternate Part Number

N/A 101940667 2735202 7003 ECOLOC 80 x 120 PL080X120 FL SLD 1350 MM 80X120 SLD 1850 MM 80X120 T301080 TLK 132 80X120
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform