CAD (0)
  • Cart is empty
Single-taper, self-centering design without mounting flange for use in through-bored components. Mounted component moves axially during installation.

View Catalog Page
Unit of Measure

Hub OD Calculator

Calculator

N/A Climax Hub OD Calculator

Drawing

Dimensional Drawing

N/A
Metric Locking Assembly

Specifications

Shaft Size

N/A 45 mm

d

N/A 1.772 in

D

N/A 2.953 in

L

N/A 0.787 in

L1

N/A 1.043 in

L2

N/A 1.358 in

L3

N/A 1.673 in

Mt

N/A 1,196 ft-lbs

Fax

N/A 16,206 lbs.F

Ps

N/A 30,815 psi

Ph

N/A 18489 psi
DN1 N/A 4.569 in

Locking Screws Quantity

N/A 7

Locking Screws Size

N/A M8 x 25

Ma-Locking Screws

N/A 26 ft-lbs

Hub Machining Tolerance

N/A 0.002 in

Shaft Machining Tolerance

N/A -0.002 in

Weight

N/A 1.50 lb

UPC Code

N/A 044861074817

Competitor Part Number

Alternate Part Number

N/A 103213606 2735159 7003 ECOLOC 45 x 75 B301045 PL045X075 FL SLD 1350 MM 45X75 SLD 1850 MM 45X75 TLK 132 45X75
  • 1 Minimum hub outside diameter based on a Pressure reduction Factor of C=1.0 and hub material with tensile yield point = 45,000 psi for carbon steel and a tensile yield point = 30,000 psi for stainless steel. For details see Hub Strength in Technical Inform